    Project Introduction

    Salt spray test is an environmental test that mainly uses artificially simulated salt spray environmental conditions created by salt spray test equipment to assess the corrosion resistance of products or metal materials. It is divided into two categories, one is the natural environment exposure test, and the other is the artificial accelerated simulated salt spray environment test. The artificial simulated salt spray environment test is to use a kind of test equipment with a certain volume space-the salt spray test box, and use the artificial method in its volume space to create a salt spray environment to evaluate the quality of the salt spray corrosion resistance of the product . Compared with the natural environment, the salt concentration of the chloride in the salt spray environment can be several times or tens of times of the general natural environment salt spray content, which greatly improves the corrosion rate, and the salt spray test is carried out on the product to obtain the results The time is also greatly reduced.

    Salt spray test classification

    (1) Neutral salt spray test (NSS test)

    It is the earliest and most widely used accelerated corrosion test method. It uses 5% sodium chloride salt water solution, and the PH value of the solution is adjusted to a neutral range (6-7) as a spray solution. The test temperature is 35 ℃, and the sedimentation rate of salt spray is required to be between 12ml/80cm2.h.

     (2) Acetate spray test (ASS test)

    It was developed on the basis of neutral salt spray test. It is to add some glacial acetic acid to the 5% sodium chloride solution, the pH value of the solution is reduced to about 3, the solution becomes acidic, and the salt mist formed finally becomes acidic from neutral salt mist. Its corrosion rate is about 3 times faster than the NSS test.

     (3) Copper salt accelerated acetate spray test (CASS test)

    It is a kind of rapid salt spray corrosion test recently developed abroad. The test temperature is 50℃. A small amount of copper salt-copper chloride is added to the salt solution, which strongly induces corrosion. Its corrosion rate is about 8 times that of the NSS test.

     (4) Alternating salt spray test

    It is a comprehensive salt spray test, which is actually a neutral salt spray test plus a constant damp heat test. It is mainly used for hollow-type complete machine products. Through the penetration of the tidal environment, the salt spray corrosion not only occurs on the surface of the product, but also occurs inside the product. It converts the product alternately under the two environmental conditions of salt spray and damp heat, and finally assesses whether the electrical and mechanical properties of the whole machine product have changed.

    Test Methods

    Test item: Salt mist test

    Reference standards: IEC60068-2-11 (GB/T2423.17), ISO 4628.3, ASTM B117, JIS-Z2371...

    Common test parameters:

    Salt spray can be divided into three categories:

    Neutral salt spray test (NSS test) (solution: PH value is adjusted in the neutral range (6.5 ~ 7.2), the test temperature is 35 ℃)

    Acetic acid salt spray test (ASS test) (solution: add some glacial acetic acid, PH value drops to about 3)

    Copper salt accelerated acetate spray test (CASS test) (the test temperature is 50 ℃, a small amount of copper salt-copper chloride is added to the salt solution)

    Test time: 16H (minimum)

    Method Standard

    GB/T 2423.17; IEC 60068-2-11; GB/T 10125; ISO 9227; ASTM B 117;

    GB.T 2423.18; IEC 60068-2-52; ASTM B 368; MIL-STD-202; EIA-364-26


    Online consultation

    Online consultation

    Recommend
    • Australian RCM certification

      Australian RCM certification

      Australian RCM certification

    • Label printer ANATEL certification

      Label printer ANATEL certification

      Label printers entering the Brazilian market, ANATEL certification is an essential passport! It is the recognition of the Brazilian Telecommunications Authority for the safety and compliance of electronic products, without which products cannot be legally sold.

    • Label printer SRRC certification

      Label printer SRRC certification

      SRRC certification is not only a guarantee of product compliance, but also a key to opening up the market.

    Salt spray test

    Salt spray test is an environmental test that mainly uses artificially simulated salt spray environmental conditions created by salt spray test equipment to assess the corrosion resistance of products or metal materials. It is divided into two categories, one is the natural environment exposure test, and the other is the artificial accelerated simulated salt spray environment test.

    Get a quote
    主站蜘蛛池模板: 亚洲国产在一区二区三区| 九九精品国产| 亚洲AV无码一区二区一二区教师| 亚洲综合一区国产精品| 国产午夜精品理论大片| 日韩中文字幕高清有码| 阿坝| 人妻中文久热无码丝袜| 亚洲黄日本午夜一区二区| 97超碰电影| 好男人中文资源在线观看| 国产精品青青青高清在线| 精品久久久久久无码中文字幕| 国产高清乱码又大又圆| 中文字幕三区| 国产毛片基地| 最近最新中文字幕在线第一页| 欧美三级在线手机版费观看| 国产精品午夜精品福利| 亚洲国产中文字幕精品| 国产精品区视频中文字幕| 怼嫩草白浆国产一区| 国产91精品福利在线观看| 久久综合丝袜日本网| 国产精品偷伦费观看一次| 亚洲精品久久麻豆蜜桃| 激情偷拍av| 色综合久久一区二区三区| 日韩人妻1区| 亚洲无码免费观看| 婷婷99狠狠躁天天躁| 久久五月丁香合缴情网| 四虎国产精品永久入口| 日韩美女久久| 国产欧美一区二区高清在线| 国产精品中文字幕二区| 久久99国产精品尤物| 国产999精品2卡3卡4卡| 99久久亚洲综合精品成人网| 亚洲一人综合| 国产一区二区三区视频|